Show simple item record

dc.contributor.advisorHuynh, Chan Khon
dc.contributor.authorHo, Le Hoang Hung
dc.date.accessioned2024-03-26T02:46:16Z
dc.date.available2024-03-26T02:46:16Z
dc.date.issued2023
dc.identifier.urihttp://keep.hcmiu.edu.vn:8080/handle/123456789/5322
dc.description.abstractBackground: Lateral flow assay (LFA) is a prevalent methodology in diagnosis due to its rapid, convenient, and affordable characteristics. However, the comparatively low sensitivity of the assay is a considerable disadvantage. A wide variety of optimization and modification in the LFA platform has been investigated, including secondary antibodies, biotin-streptavidin binding, silver nanoparticles, the substitution of electrochemical luminescence or modification of the flow, etc. This study aims to improve the colorimetric SARS-CoV-2 LFA's sensitivity by the capture antibodies orientation protein A due to its high affinity to the Fc region of antibodies. Method: The gold nanoparticles (AuNPs) based colorimetric LFA test for SARS-CoV-2 was designed based on the sandwich ELISA principle. Monoclonal antibodies (Anti-SARS-CoV-2 N mouse antibodies 7B3) and detection antibodies (Anti-SARS-CoV-2 Nucleocapsid Recombinant Rabbit Monoclonal Antibody 3E8A5) are used to capture the SARS-CoV-2 protein N. For capture antibody orientation, protein A is added to the nitrocellulose membrane before dotting the capture antibodies. Different capture antibodies and protein A ratios ranging from 1:3 to 1:0.5 (Molar: Molar ratio) were investigated. To test the effectiveness and limit of detection (LoD) of the designed system, half-strip models, including nitrocellulose membrane with pre-immobilized protein A/capture antibody and wicking pad, were assembled. Samples containing protein N at different concentrations (1 µg/mL, 100 ng/mL, 10 ng/mL, 1 ng/mL to 100 pg/mL) were mixed with AuNPs-detection antibody conjugates at 1:5 (v/v ratio) then loaded to the half-strips. Finally, the full-strip fabrication procedure is processed with the combination of the modified half-strip fabrication procedure (without sample loading step), conjugate pad, and sample pad pretreatment. Band signals were analyzed by both naked eyes and ImageJ mean Grayscale Value (GSV) measurement. All experiments, except for the conjugation characterization and the full-strip effectiveness evaluation, were triplicated. For statistical analysis, the Student's t-test and One-way ANOVA with the Tukey HSD post-hoc multiple comparison test were used for the variance comparisons across the means of data groups. The results were considered statistically significant when p-value < 0.05. Result: A molar ratio 1:1 was shown to be the optimal capture antibody: protein A ratio as there was no excess protein A. In the initial half-strip fabrication, the strips faced the problem of slow intensity signal revealing as positive signal reached GSV = 221.320 ± 0.645, which is extremely close to the GSV = 231.997 ± 1.885 of the negative control and is difficult to distinguish from the negative sample by the naked eye. With the modification in non-specific blocking methodology by directly mixing BSA 2.5% (w/v) to the sample mixture instead of pretreating on the membrane, the signal band of the half-strip reveals a denser pink color with a clear signal at GSV = 209.506 ± 1.041 compared to the negative threshold and the signal of the strip before being optimized (p value < 0.05). In the limit of detection experiments, LFA strips without protein A and commercialized kit (eDiagnosis Covid-19 antigen Rapid Test Kit) reach a similar antigen concentration of 1 ng/mL as the limit of detection. In the presence of protein A, the limit of detection of the LFA reached the antigen concentration of 100 pg/mL, with a stable GSV of 216.296 ± 1.071, being significantly different from and much lower than the intensities of negative results threshold, without protein A half-strip, and commercialized test kit (p-value < 0.05). The results indicate protein A has a significant impact on enhancing the sensitivity of the SARS-CoV- 2 half-strip. The functional full-strip is also fabricated subsequently and can distinguish positive and negative samples with clear signal bands. Conclusion: Protein A is the key factor for the 10-times enhancement of the Protein N SARS CoV-2 detecting Lateral Flow Test strip's sensitivity as the Limit of Detection decreases from 1 ng/mL to 100 pg/mL antigen concentration.en_US
dc.language.isoenen_US
dc.subjectLateral flow assayen_US
dc.subjectSARS-CoV-2 Nucleocapsid Recombinant Proteinen_US
dc.titleDevelopment Of A Lateral Flow Assay With Orientated Capture Antibody For The Detection Of Sars-Cov-2 Nucleocapsid Protein In Salivaen_US
dc.typeThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record